About Healthcare Professionals Patients News Join Us Investor Relations Contact Us
CN EN

Thrombite™ Clot Retriever Device

More efficient choice of recanalization

OVERVIEW
Thrombite™ Clot Retriever Device

HELICAL OPEN-SIDE STRUCTURE

HIGHER ACUTE RECANALIZATION RATE

The  Thrombite™ Clot Retriever Device, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

Thrombite™ Clot Retriever Device

CLOT RETRIEVAL DEVICES FEATURES

CLOT RETRIEVAL DEVICES FEATURES

HELICAL OPEN-SIDE STRUCTURE

  • enables Thrombite™ retriever to efficiently entwine and clamp the clot

  • assures clot retention for confident removal and revascularization


OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration


EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

CLOT RETRIEVAL DEVICES FEATURES
Radiopaque markers on the distal end of the device increase device visibility
Radiopaque markers on the distal end of the device increase device visibility
  • 3 markers for the sizes with 3.0 and 4.0mm diameter

  • 4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process
Advanced stent surface treatment process
RADIAL FORCE
  • High radial force is designed for clot integration at the initial stage of stent expansion

  • Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE

How a Stent Retriever Procedure Is Performed

Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body. 

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE
STENT RETRIEVAL DEVICE STRUCTURE
ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE
Thrombite™Product codeDiameter D(mm)Recommended Vessel Diameter(mm)
Min.        Max.
Recommende Microcatheter ID (inch)Working Length A(mm)Stent Length B(mm)System Length(mm)
3MMCRD-3-1531.53.00.2115271900
CRD-3-2031.53.00.2120321900
CRD-3-2531.53.00.2125371900
CRD-3-3031.53.00.2130421900
4MMCRD-4-1542.04.00.2115271900
CRD-4-2042.04.00.2120321900
CRD-4-2542.04.00.2125371900
CRD-4-3042.04.00.2130421900
5MMCRD-5-1552.55.00.02715271900
CRD-5-2052.55.00.02720321900
CRD-5-2552.55.00.02725371900
CRD-5-3052.55.00.02730421900
6MMCRD-6-1563.05.50.02715271900
CRD-6-2063.05.50.02720321900
CRD-6-2563.05.50.02725371900
CRD-6-3063.05.50.02730421900


Thrombite Clot Retrieval Device Resources

Thrombite Clot Retrieval Device Resources

VIDEOS OF CLOT RETRIEVAL DEVICE
Thrombite™ Clot Retriever Device

  

INDICATIONS OF CLOT RETRIEVAL DEVICE
Thrombite™ Clot Retriever Device

The Thrombite™ Clot Retriever Device is intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Related Products